![Beko DRYPOINT AC 410 Скачать руководство пользователя страница 36](http://html.mh-extra.com/html/beko/drypoint-ac-410/drypoint-ac-410_installation-and-operating-manual_28452036.webp)
Installation and operating manual
EN
36 DRYPOINT
®
AC 410 – 495 | DRYPOINT
®
AC 410 – 495 MS
7. Maintenance and servicing
7.1. Maintenance intervals
7.1.1. Filter elements
To ensure trouble-free operation of the plant and its components, the filter elements must be replaced when a
message instructing you to do so is displayed, or latest after 8760 operating hours or 1 year.
7.1.2. Adsorbent
Liquid oil can destroy the adsorbent, which results in significantly impaired plant performance. We therefore
strongly recommend replacing the filters at regular and appropriate intervals.
Non-compliance with the operating conditions (i.e. excessively high inlet temperature or insufficient operating
pressure) can result in an overload of the adsorbent, causing malfunction of the plant.
To ensure trouble-free operation of the plant and its components, the adsorbent must be changed when a message
instructing you to do so is displayed, or latest after 26,250 operating hours or 3 years.
7.1.3. Service inspection tasks
1. Visual inspection of the adsorption dryer and the filters
2. Inspection of the prefilter and afterfilter elements and replacement of the filter elements
3. Inspection and cleaning of the condensate discharge
4. Inspection and testing of all filters; clean and lubricate, if necessary
5. Inspection of the silencers; replace, if necessary
6. Inspection of all electrical components and indicators
7. Inspection of the adsorbent and replacement according to service interval
8. Pressure leakage test
9. Test run and final check
10. Testing of adsorption dryer switching
11. Restarting of plant
12. Compressed air quality check
13. Documentation of inspection tasks with date, etc. in service report
7.1.4. Service intervals
Service
A (annual service interval):
after 52500 cycles or 8760 hours
Service
B (3-yearly service interval):
after 157,500 cycles or 28,000 hours
7.1.5. Service tasks
The table below provides and overview of the service tasks and their purpose for services A and B.
Service
Scope
Cycle
Service A
Filters
Wearing parts
52,500 cycles
8760 hours - max. 10,000 hours
Service B
Adsorbent and
complete service A
157,500 cycles
26,250 hours - max. 28,000 hours
NOTE
Content of service kit
The prefilter and afterfilter elements and the BEKOMAT
®
wearing parts are not included in
the service kits and must be ordered separately.
Содержание DRYPOINT AC 410
Страница 2: ...Installation and operating manual EN 2 DRYPOINT AC 410 495 DRYPOINT AC 410 495 MS ...
Страница 52: ...Installation and operating manual EN 52 DRYPOINT AC 410 495 DRYPOINT AC 410 495 MS ...
Страница 55: ...EN Installation and operating manual DRYPOINT AC 410 495 DRYPOINT AC 410 495 MS 55 ...