2.6. Technical data
DRYPOINT
®
AC
410
415
418
423
430
438
455
465
485
495
Connection
½"
1"
1"
1"
1"
1 ½"
2"
2"
2"
2"
Medium
Compressed air/nitrogen
Volumetric flow rate (m³/h)*
100
150
175
225
300
375
550
650
850
1000
Operating pressure min./max.
4 ... 16 bar
Max. inlet temperature
50 °C
Ambient temperature min./max.
+4 ... +50 °C
Air humidity
Max. 100 % at 45 °C
Ambient conditions
0 ... Altitude 0 - 2000 m (indoor installation)
Pressure dew point
Min. -40 °C, optional -70 °C < PDP< -40 °C
Working principle
Fully automated, cold-regenerating, continuous operation
Electrical data
Operating voltage (depending
on model)
230 V / 50 ... 60 Hz (± 10 %), optional 115 V / 50 ... 60 Hz (± 10 %), 24 VDC (± 10 %)
Mains cable wire cross-section
AC: 3 x 0.75 mm
2
DC: 2 x 0.75 mm
2
Power consumption and internal
fusing
max. 40 W / 2 A slow-acting, 250 V, ceramic tube fuse
Contact rated voltage
relay solenoid valves
230 V / 115 VAC / 24 VDC
Contact rated current
relay solenoid valves
8 A (ohmic load)
Contact rated voltage
relay alarm
125 V
Contact rated current
relay alarm
1 A (ohmic load)
Protection class
IP 54
Overvoltage category
2
Purity of compressed air at adsorption dryer outlet
Residual water content
DRYPOINT
®
AC 410 – 495: 0.11 mg/m
3
DRYPOINT
®
AC 410 – 495 MS: 0.0027 mg/m
3
Adsorbent in pressure vessels
DRYPOINT
®
AC 410 – 495
Aluminium oxide
DRYPOINT
®
AC 410 – 495 MS:
Molecular sieve
* Volume flow rates for PDP -40
C, in relation to 20
C ambient temperature, 1 bar
(abs), an operating pressure of
7 bar (gauge) and a compressed air inlet temperature of 35
C (saturated)
Correction factor
Inlet
temperature
Operating overpressure (bar)
4
5
6
7
8
9
10
11
12
13
14
15
16
25 °C
0.75
0.90
1.05
1.20
1.35
1.50
1.65
1.80
1.95
2.10
2.25
2.40
2.55
30 °C
0.69
0.83
0.96
1.10
1.24
1.38
1.51
1.65
1.79
1.93
2.06
2.20
2.34
35 °C
0.63
0.75
0.88
1.00
1.13
1.25
1.38
1.50
1.63
1.75
1.88
2.00
2.13
40 °C
0.50
0.60
0.70
0.80
0.90
1.00
1.10
1.20
1.30
1.40
1.50
1.60
1.70
45 °C
0.44
0.53
0.61
0.70
0.79
0.88
0.96
1.05
1.14
1.23
1.31
1.40
1.49
50 °C
0.31
0.38
0.44
0.50
0.56
0.63
0.69
0.75
0.81
0.88
0.94
1.00
1.06