![Beko DRYPOINT AC 410 Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/beko/drypoint-ac-410/drypoint-ac-410_installation-and-operating-manual_28452028.webp)
Installation and operating manual
EN
28 DRYPOINT
®
AC 410 – 495 | DRYPOINT
®
AC 410 – 495 MS
3.1. Warning
NOTE
Modifications to the plant
Removing the filter or the bulk materials from the system without replacing them immediately
can result in a significant impairment of the plant performance and function.
•
Never remove individual filters or bulk material from the system without replacing them
before restarting the plant.
• For installation work, you can remove the housing cover plates for servicing and installation access.
• The plant can be supplied with compressed air from any conventional compressor. You must however ensure
that the compressed air at the plant inlet meets the feed conditions for compressed air. Make sure that the air
intake duct of the compressor is not at a position where the ambient air is particularly contaminated (e.g. near
machine exhaust pipes or other sources of contamination).
NOTE
Removing packaging
Carefully remove all packaging from the plant.
If the plant has been damaged during transport, or if parts are missing, notify the
manufacturer and the transport company without delay.
If necessary, document the damage and inform the manufacturer.
3.2. Installation area
•
The adsorption dryer must be installed in an upright position. Observe the flow direction markings.
•
Ensure that there is no risk that the air flows through the plant in the opposite direction to the design flow
direction (exception: intermittent operation).
• Do not attempt to start the plant against a large volume of air that is under atmospheric or even lower pressure
(see also “2.6. Technical data”).
• To prevent this, we recommend installing an automatic start-up system (optional equipment).
•
Do not run several plants in parallel without providing separate volumetric flow limitation devices.
• If the compressor is operated in discontinuous mode, the plant control can be linked to the compressor control
(option: intermittent operation, see “3.5. Intermittent operation”). Always ensure that a regeneration cycle that
has been started is completed even after the compressor has been shut off.
• If the ambient temperature at the location of installation of the plant is likely to drop below +2 °C, install an
auxiliary heater (optional equipment) to protect the plant against frost.
• Clean the surface on which you want to place the plant and make sure that the system is accessible from all
sides. There must be sufficient room for the replacement and servicing of the plant.
•
The floor must be level and able to carry the weight of the plant.
• The adsorption dryer must be protected against vibration caused by other units.
• Position the plant so that it can be connected to a power socket (with the supplied power cable) or to a mains
disconnect device (with external power supply).
Содержание DRYPOINT AC 410
Страница 2: ...Installation and operating manual EN 2 DRYPOINT AC 410 495 DRYPOINT AC 410 495 MS ...
Страница 52: ...Installation and operating manual EN 52 DRYPOINT AC 410 495 DRYPOINT AC 410 495 MS ...
Страница 55: ...EN Installation and operating manual DRYPOINT AC 410 495 DRYPOINT AC 410 495 MS 55 ...