EN
Installation and operating manual
DRYPOINT
®
AC 410 – 495 | DRYPOINT
®
AC 410 – 495 MS
27
DRYPOINT
®
AC
Regeneration air flow rate (m³/h)
at 1 bar, 20 °C
Air exit flow rate (m³/h)
at 1 bar, 20 °C
Size
Standard
MS
Standard
MS
410
15.0
20
81.6
75.4
415
23.0
30
121.7
113.1
418
26.3
35
142.7
132.0
423
34.0
45
183.2
170.0
430
45.0
60
244.7
226.2
438
56.0
75
306.1
282.8
455
83.0
220
447.9
414.7
465
98.0
130
529.5
490.1
485
128.0
170
692.6
640.9
495
150.0
200
815.5
754.0
3. Installation
DANGER
External forces and torques
The plant must be protected against external forces and torques, as these could cause
damage, leading to leakage or even malfunction of the plant.
•
• Ensure that no external forces and torques are transferred to the plant through the on-
site piping system. Otherwise, the permissible load on the system might be exceeded.
If necessary, the plant operator must carry out tests or make modifications to the on-site
installations.
• The adsorption dryer must be protected against vibration caused by other units. If
necessary, the operator must take suitable measures to prevent the propagation of
vibration.
NOTE
Responsibility for proper installation
• The operator is responsible for the proper installation of the adsorption dryer, and of the
piping to and from the plant.
• The manufacturer is
not
responsible for the planning or installation of safety devices that
prevent overvoltage, short circuits or overloads.
NOTE
Integration into existing piping
If the plant is to be installed into an existing pipeline, the operator must take into account that
the pipes downstream of the place of installation of the dryer might be contaminated. It might
therefore be necessary to clean or replace this piping sections and the components.