DRYPOINT
®
AC 410 – 495 | DRYPOINT
®
AC 410 – 495 MS
7
DANGER
Disabling of safety devices
If safety devices are disabled or not working properly, there is a risk of serious injury, plant
malfunction and/or damage to property.
• Never disable or bridge the safety devices of the plant.
• Safety devices that prevent operation of the plant at inadmissible conditions (e.g.
excessive pressure or temperature) are not included in the standard scope of delivery.
• Should they be supplied as installed accessories, they must never be disabled
• or bridged.
DANGER
Excessive pressure / temperature
Suitable measures must be taken to ensure that the pressure in the plant components does
not exceed the permissible operating pressure.
• It is the responsibility of the plant operator to protect the plant against excessive pressure
build-up.
• Take suitable measures to protect the compressor and the compressed air system
downstream of the adsorption dryer.
• Take suitable technical precautions to ensure that the temperature at operating pressure
does not exceed the maximum permissible operating temperature of the individual
components.
• The plant operator must take suitable measures to ensure that the temperature of the
incoming gas does not exceed the maximum permissible operating temperature of the
plant.
• If the plant is pressurised to operating pressure, the operator must ensure that the
maximum permissible operating temperature is not inadvertently exceeded by ambient
conditions at the site of installation.
DANGER
Fire safety
A fire in the plant might result in serious injury or damage to materials.
•
Safety devices that prevent excessive pressure build-up as a consequence of a fire are
not included in the standard scope of delivery.
• If there are potential ignition sources at the place of installation of the plant, the operator
must take suitable safety measures to ensure that the permissible operating parameters
of the plant are not exceeded.
NOTE
Pressure vessel – stress from alternating loads
The alternating load rate per year depends on the plant cycle times and the type of the plant.
The plant design is based on a service life of 10 years.
• In Germany, the pressurised walls must be tested at least every 5 years (internal test),
and strength test (pressure test) must be completed at least every 10 years.
• Observe the statutory regulations that apply at the place of installation of the plant and
schedule all necessary tests with the respective notified body.