Commissioning
EL125x, EL2258
118
Version: 2.5
EL1259
Macrocycle time [µs, typical]
Microcycle time [µs, typical]
1 Ch. In + 1 Ch. Out
90
8
2 Ch. In + 2 Ch. Out
160
11
4 Ch. In + 4 Ch. Out
180
18
8 Ch. In + 8 Ch. Out
200
30
EL2258
Macrocycle time [µs, typical]
Microcycle time [µs, typical]
1 Ch.
70
7
2 Ch.
90
8
4 Ch.
110
10
8 Ch.
120
15
The microcycle time defines the feasible time resolution of the input capture/output issue.
PDO definition
The process data for inputs and outputs can specified as "predefined PDO" or freely combined:
•
Selection via "predefined PDO"
Fig. 149: Setting multi-timestamping via "predefined PDO"
Several pre-configured combinations of channel number and MTSF are offered. We recommend selecting
the process data compilations in this way.
•
Free compilation
Alternatively, the number of used channels and MTSF per channel can be set as a free compilation via
the PDO assignment. The process data objects (PDO) to be transferred cyclically are activated from
the inputs/outputs list in the System Manager.
Fig. 150: Free selection of the PDO
The meaning of the individual PDOs can be found in the CoE overview. Please note: