PStick Des data set
(7251)
If a data set is selected under prog. no. 7250, under prog. no 7251 the data set
name is displayed. For backup sticks the data set name is displayed in the format
BUYYMMDDHHMM
(BU for backup and date of backup: Year, Month, Day, Hour,
Minute). As soon as a data set number is selected, the text is displayed for the
data set description.
PStick command
(7252)
-
No operation
: this is the base condition. As long as no operation is active on the
stick, this command is displayed.
-
Reading from stick
: starts reading the data from the stick. This operation is only
possible with READ or READ/WRITE sticks. The data of the set data set is copied
in the LMS control. Beforehand is checked whether the data set may be brought
in. If the data set is incompatible, it may not be brought in. The display resets to
no operation, displays an error message. The text Read from stick remains until
the operation is completed or an error occurs. As soon as the data transmission
begins, the LMS control goes in a parameterization position. As soon as the pa-
rameter is transferred, the LMS control must be unlocked after ending the
transmission. Error 183 parameterization is displayed.
-
Writing on stick
: Starts writing the data from the LMS control to the stick. This
operation is only possible with WRITE or READ/WRITE sticks. The data is written
in the previously set data set. Before writing of the data begins, it is checked
whether the data fits on the stick and the respective customer number is cor-
rect. The text Writing to stick remains until the operation is completed or an
error occurs.
PStick progress
(7253)
The read or write progress is displayed as a percentage. If no operation is active or
an error shows up, 0% is displayed.
State PStick
(7254)
-
No stick
: The LMS control detected no stick (possibly the stick is not inserted).
-
Stick ready
: Basic condition, stick is detected, no action active, no error present.
-
Writing on stick
: Data is copied (backup) from he LMS control to the stick.
-
Reading from stick
: Data is transferred from the stick in the LMS control.
-
EMC test active
: Special function EMC tests in the lab. A special compiler switch
must be set for this.
-
Writing error
: An error occurred when copying the data from the LMS control to
the stick. The operation was aborted.
-
Reading error
: An error occurred when copying the data from the stick to the
LMS control.. The operation was aborted. The control LMS is locked. Status
change to read lock.
-
Incompatible data set
: Data set does not match LMS control. Compatibility con-
ditions are not met. The data set can not be brought in.
-
Wrong stick type
: Stick type does not match selected action. E. B. read from wri-
te stick or write to read stick is not possible.
-
Stick format error
: incorrect customer number on the stick or data format on
the stick is not recognised and cannot be evaluated by the LMS control.
-
Check data set
: during transmission of a data set from the stick to the LMS con-
trol a problem appeared, but it did not lead to an abort.
-
Data set disabled
: the data set may not be transferred into the LMS control (re-
ad protected).
-
Reading disabled
: the parameterization position is in the
ABORT
condition. Only
limited actions are possible to remove the parameterization position.
Input/output test
Input/output tests
(7700 - 7872)
Tests for checking the connected components for function.
Programming
116
358 436 08.10
Содержание LUNA HT 1.280
Страница 1: ...Installation operation and maintenance manual Condensing gas boiler Power HT 1 230 1 280 1 320...
Страница 8: ...2 6 Conformity declaration Safety 8 358 436 08 10...
Страница 10: ...Technical Data 10 358 436 08 10...
Страница 12: ...Technical Data 12 358 436 08 10...
Страница 13: ...3 3 Wiring Diagram Fig 2 Wiring Diagram Technical Data 358 436 08 10 13...
Страница 21: ...Before installation 358 436 08 10 21...
Страница 23: ...Wiring plan Before installation 358 436 08 10 23...
Страница 25: ...Wiring plan Before installation 358 436 08 10 25...
Страница 27: ...Wiring plan Before installation 358 436 08 10 27...
Страница 29: ...Wiring plan right EC three Before installation 358 436 08 10 29...
Страница 30: ...Wiring plan left EC three Before installation 30 358 436 08 10...
Страница 31: ...4 9 Legend Before installation 358 436 08 10 31...
Страница 126: ...Fig 30 Boiler view Maintenance 126 358 436 08 10 gas connection supply air conntection heating return heating flow...
Страница 142: ...Space for notes 142 358 436 08 10...
Страница 143: ...Space for notes 358 436 08 10 143...