The efficiency of this appliance has been measured as specified in BS 7977 - 1 and the
result is as below :
Model
Efficiency % (Gross)
Amour, Aspect, Eclipse, Landscape, Serenity and Visia.
51
Aspect Glass, Tranquility and Fascination.
45
Fascination when converted to LPG.
46
The gross calorific value of the fuel has been used for this efficiency calculation. The
test data from which it has been calculated has been certified by Advantica Certification
services (0087). The efficiency value may be used in the UK Government's Standard
Assessment Procedure (SAP) for energy rating of dwellings.
The convertion of
net
efficiency to
gross
was achieved by multiplying the net efficiency
by the following conversion factor from Table E3 of SAP 2005, rounding down to the
nearest whole number.
This product uses fuel effect pieces containing Refractory Ceramic Fibres (RCF),
which are man-made vitreous silicate fibres. Excessive exposure to these materials
may cause irritation to eyes, skin and respiratory tract. Consequently, it is
important to take care when handling these articles to ensure that the release of
dust is kept to a minimum. To ensure that the release of fibres from these RCF
articles is kept to a minimum, during installation and servicing we recommend that
you use a HEPA filtered vacuum to remove any dust and soot accumulated in and
around the fire before and after working on the fire. When replacing these articles
we recommend that the replaced items are not broken up, but are sealed within a
heavy duty polythene bag, clearly labelled as RCF waste. RCF waste is classed as a
stable, non-reactive hazardous waste and may be disposed at a landfill licensed to
accept such waste. Protective clothing is not required when handling these articles,
but we recommend you follow the normal hygiene rules of not smoking, eating or
drinking in the work area and always wash your hands before eating or drinking.
This appliance does not contain any component manufactured from asbestos or
asbestos related products.
Page 7
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
Gas
Conversion factor from
net
to
gross
efficiency
Natural Gas
0.901
LPG
0.921