11.5 Fitting the lower hotbox baffle to the
‘Fascination’model.
The lower hotbox baffle is supplied for use when
fitting the ‘Fascination’ model into elevated
builders openings or ‘Hole in the wall’
installations.
1.
Locate the baffle as in figure 25.
2.
Secure the baffle using the screw supplied.
12. FITTING THE CERAMIC FUEL EFFECT
The installer and owner guide for the ceramic fuel effect is supplied with the ceramic
fuel effect. It is important that the guide for the ceramic fuel effect be placed inside or
attached to this guide and handed to the customer following completion of the ‘final
review’ section.
13. FULL OPERATING CHECKS
13.1 Check the control settings.
Please note:
When first turned on from cold, the flames will appear predominantly blue.
When operating the fire for the first time, some vapours may be given off which could
set off smoke alarms in the vicinity. These vapours are quite normal with new
appliances. They are totally harmless and will disappear after a few hours use
.
13.1.1
Lighting the burner.
Open the isolating valve on the ‘T’ connector. Screw on the end cap and test for leaks.
Depress the control knob and rotate it anticlockwise to the pilot ignition position. A
‘click’ will be heard as the integral piezo operates. A flame should appear at the pilot to
the left hand side of the ceramic fuel effect. When a flame appears at the pilot keep the
control knob depressed and hold the pilot ignition position for five seconds. When the
control knob is released the pilot flame should remain lit.
If there are no sparks check the spark gap between electrode wire and pilot tip.
Page 28
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
Figure 25. Fitting the lower hotbox
baffle to the ‘Fascination’ model.