3. APPLIANCE DATA
* When converted using conversion kit number 05754M1.
The appliance data label is located on a plate at the base of the fire. This can be seen by
lowering the bottom front cover of the fascia.
Page 6
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
Gas
Natural (G20)
Propane (G31)*
Inlet Pressure
20mbar
37mbar
Aspect, Amour, Eclipse,
Landscape, Serenity and
Visia - Input Max. (Gross)
5.1kW (17,400 Btu/h)
Not available
Aspect, Amour, Eclipse,
Landscape, Serenity and
Visia - Input Min. (Gross)
3.0kW (10,236 Btu/h)
Not available
Aspect Glass and Tranquility
Input Max. (Gross)
5.2kW (17,400 Btu/h)
Not available
Aspect Glass and Tranquility
Input Min.(Gross)
3.1kW (10,236 Btu/h)
Not available
Fascination - Input Max.
(Gross)
5.5kW (18,766 Btu/h)
5.0kW (17,060 Btu/h)
Fascination - Input - Min.
(Gross)
3.1kW (10,577 Btu/h)
4.6kW (15,695 Btu/h)
Inlet Test Pressure (Cold)
20.0 ± 1.0mbar (8.0 ± 0.4in
w.g.)
37.0 ± 1.0mbar (14.85 ±
0.4in w.g.)
Gas Connection
8mm pipe
8mm pipe
Burner Injector
Stereomatic Cat. 82 Size 065
StereomaticSize 110
Pilot & Atmosphere Sensing
Device
Copreci Ref. O.D.S
21500/166
Copreci Ref. O.D.S
21500/166 Fitted with RBM
180 - 02 injector
Ignition
Integral piezo (Mounted on
gas valve)
Integral piezo (Mounted on
gas valve)
Aeration
Non-adjustable
Non-adjustable