7. IGNITION CHECK
Before attempting to install, it is
worth checking that the ignition
system performs satisfactorily.
Set the control knob to the off
position. Depress the control knob
and rotate it anticlockwise to the
pilot ignition position. A 'click' will
be heard as the integral piezo
operates. A spark should be seen
between the electrode and pilot tip.
If there is no spark check the
following: -
!
Ensure that the electrode lead is connected to the terminal at the base of the
electrode.
!
If the above is correct, check for damage to the electrode lead.
8. GAS SUPPLY CONNECTION
A nut and olive are provided for an 8mm pipe inlet connection to the ‘T’ connector at
the bottom front of the appliance. The ‘T’ connector can be rotated to allow a
connection from any rear-concealed connection. The ‘T’ connector includes a valve for
isolating the gas supply and a pressure test point.
The supply pipe must be rigid material. Flexible pipe must not be used.
Concealed supply pipe connection.
If a concealed connection from inside the fireplace is required then
,
before the
appliance is fitted into the fireplace
it will be necessary to extend the supply line so
that it will project through the hole in the back of the hotbox and run to the ‘T’
connector at the front. The pipe run from the supply line up to the rear opening in the
hotbox must be kept away from the area which will be taken by the hotbox when it is
installed. Note that the centre of the appliance inlet ‘T’ connector is 25mm above the
fireplace floor. The inlet ‘T’ connector should be fitted to the supply pipe at this stage.
Page 20
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
Figure 8. Ignition operation
(On ‘Landscape’ , ‘Visia’ and ‘Serenity’ models
the control knob and indicator button will be
spaced away from the support leg)