13.1.2
Operating the burner.
Turn the control knob anti-clockwise to ‘HIGH’ (Depress the knob slightly to get past
the pilot ignition position). The main burner should now light. Depress the control knob
slightly to release from the ‘HIGH’ position and turn back (clockwise) to ‘LOW’. While
turning, the burner flames should gradually become lower but remain alight. Depress
the control knob slightly to release from the ‘LOW’ position and turn back (clockwise)
to the Pilot ignition position. The main burner should extinguish but the pilot should
remain alight. Depress the control knob slightly and turn back (clockwise) to turn OFF.
This will extinguish the pilot.
13.2 Check for spillage.
1.
Close all doors and windows in the room containing the appliance.
2.
Light the appliance and set the control to the
‘High’ position.
3.
Leave the appliance on for five minutes.
4.
The smoke match should be placed
horizontally into the hotbox at the right hand
side (See figure 26).
The installation is satisfactory if the smoke is
drawn into the appliance.
If the smoke is not drawn into the appliance
leave the appliance alight at the maximum
setting for a further ten minutes and then repeat
the test. If the smoke is still not drawn into the
appliance inspect the sealing to the fireplace
surround. If the sealing is satisfactory but the
appliance is installed with the flue restrictor (See
section 9 point 14) remove the restrictor, reseal
the appliance and retest. If smoke is still not
drawn into the appliance
disconnect the appliance and seek expert advice.
5.
If the above test is satisfactory open all internal connecting doors, hatches, etc. in the
room. Keep all doors and windows that open to the outside of the building closed.
Recheck for spillage as above. If an extractor fan is installed in the same room as the
appliance or a connecting room, check that spillage does not occur with the fan
operating and all doors and other openings between the fan and the appliance open.
If the smoke is drawn into the appliance, continue with the installation. If the test is not
satisfactory
disconnect the appliance and advise the customer of the cause of
failure
.
Page 29
INSTALLER GUIDE
©
Baxi Heating U.K. Limited 2007.
A spillage check must be made before leaving the installed appliance with the
customer. Make this with all the ceramic fuel effect pieces in position
.
Figure 26. Smoke match tube