Error handling
Instruction handbook
b maXX
BM4400, BM4600, BM4700
Document No.: 5.12008.07
Baumüller Nürnberg GmbH
252
9.4
2 encoders can be connected to a
b maXX
4000 at most. Accordingly errors can appear
in function module 1 and function module 2. The term „encoder 1“ or „encoder 2“ in the
column „device part“ stands for one of the five currently existing encoder module types.
80
CRC has generated an error
Check the encoder cable and the encoder connection
81 Invalid
command
82
Error in response telegram
83
Alarm bit is set
Restart
b maXX
4000
84
Memory is used
Check the encoder cable and the encoder connection
85
Incorrect data checksum
86
Motor data length and/or data version of
encoder and controller firmware are not identi-
cal
87
No EnDat interface
88
Exceeding the evaluable transmission format
Use another type of length measurement system
89
Exceeding the evaluable measuring step
90
Signal period length < measuring step length
91
EnDat 2.2: Error initializing master module
Exchange module (standard controller) or exchange controller (ES
controller)
92
EnDat 2.2: Timeout measuring the signal trans-
fer time
Exchange encoder cable or module (standard controller) or change
controller (ES controller)
93
EnDat 2.2: Error - signal transfer compensation
is switched-off
Exchange module (standard controller) or exchange controller (ES
controller)
94
EnDat 2.2: Encoder type does not support
EnDat2.2 (command set, power supply, clock
frequency)
Use suitable encoder type
95
EnDat 2.2: RM bit is not set, reference of
encoder absolute position is not available
96
Error lightning
Exchange encoder
97
Error signal amplitude
98
Error position value
99
Error overvoltage
Exchange module (standard controller) or exchange controller (ES
controller)
100
Error undervoltage
101
Error overcurrent
102
Error battery
Exchange encoder
103 -111
reserved
112
Position error detected at multiple request
Check encoder cable or installation
113
Error triggered by additional info 1
Refer to encoder-dependent definition of additional information 1
114
Error triggered by additional info 2
Refer to encoder-dependent definition of additional information 2
115
Error triggered by additional info 3
Refer to encoder-dependent definition of additional information 3
116
Error triggered by additional info 4
Refer to encoder-dependent definition of additional information 4
117
Error triggered by additional info 5
Refer to encoder-dependent definition of additional information 5
118
Error triggered by additional info 6
Refer to encoder-dependent definition of additional information 6
119
Error triggered by additional info 7
Refer to encoder-dependent definition of additional information 7
Error code
Meaning
Troubleshooting
Содержание b maxx BM4400
Страница 137: ...Design and Operation Instruction handbook b maXX BM4400 BM4600 BM4700 Document No 5 12008 07 137 of 358 4 ...
Страница 322: ...Instruction handbook b maXX BM4400 BM4600 BM4700 Document No 5 12008 07 Baumüller Nürnberg GmbH 322 of 358 A ...
Страница 358: ...Instruction handbook b maXX BM4400 BM4600 BM4700 Document No 5 12008 07 Baumüller Nürnberg GmbH 358 of 358 Notes ...
Страница 359: ......