Mains filters
Instruction handbook
b maXX
BM4400, BM4600, BM4700
Document No.: 5.12008.07
Baumüller Nürnberg GmbH
298
11.3
11.3.5 Mains filter selection
TT/TN system
1)
Rated temperature = 50° C
NOTE!
The rated current of the filters that are used must be larger than or have same RMS-
value as the actual power suppl.y current (actual power supply current = RMS-value
of the power supply current during the entire cycle time of the drive). During short-
time operation (S3), the RMS-value is calculated as follows:
I
rms
1
T
---
i
2
0
T
dt
=
I
rated AC
1)
Typ
Part No.
7 A BFN-3-1 - 0007 - 001
314277
16 A BFN-3-1 - 0016 - 001
314278
30 A BFN-3-1 - 0030 - 001
314279
42 A BFN-3-1 - 0042 - 001
314280
56 A BFN-3-1 - 0056 - 001
314281
75 A BFN-3-1 - 0075 - 001
314282
100 A BFN-3-1 - 0100 - 001
314283
130 A BFN-3-1 - 0130 - 001
314284
150 A
EPCOS B84143A0150R410
437618
180 A BFN-3-1 - 0180 - 001
314285
250 A BFN-3-1 - 0250 - 001
373891
320 A BFN-3-1 - 0320 - 001
439384
BFN-3-1 - 0320 - 101
373896
400 A BFN-3-1 - 0400 - 101
373900
600 A BFN-3-1 - 0600 - 001
373901
BFN-3-1 - 0600 - 101
419997
1000 A BFN-3-1 - 1000 - 101
423683