Technical Data
Instruction handbook
b maXX
BM4400, BM4600, BM4700
Document No.: 5.12008.07
111
3
P
D
= 0,417 kW < 1,5 kW
and
0 K
T = 0,38 K
20 K
and
T
1
to T
5
400 K
T
3
=
=
= 140.98 K
T
4
=
=
= 138.88 K
T
5
=
=
= 151.35 K
T
6
=
=
= 83.78 K
T
= T
6
- T
0
= 83.78 K - 83.4 K
= 0.38 K
T
2
TM
–
e
C3 t
off
_2
TM C2 Ps_3 t
on
_3
+
+
=
132
·
,06K 83,4K
–
e
0,9169s
–
1
–
1,79s
83,4K 0,01605K/Ws 20000W 0,15s
+
+
=
T
4
T
3
TM
–
e
C3 t
off
_3
TM C2 Ps_4 t
on
_4
+
+
=
140
·
,92K 83,4K
–
e
0,9169s
–
1
–
6,85s
83,4K 0,01605K/Ws 23000W 0,15s
+
+
=
T
4
TM
–
e
C3 t
off
_4
TM C2 Ps_5 t
on
_5
+
+
=
138
·
,81K 83,4K
–
e
0,9169s
–
1
–
1
,85s
83,4K 0,01605K/Ws 24000W 0,15s
+
+
=
T
5
TM
–
e
C3 t
off
_5
TM
+
151
·
,29K 83,4K
–
e
0,9169s
–
1
–
5,65
s
83,4K
+
=
=
151
·
,29K 83,4K
–
e
0,9169s
–
1
–
5
,65s
83,4K
+
=
The internal brake resistor can be used for this application.