Installation
Instruction handbook
b maXX
BM4400, BM4600, BM4700
Document No.: 5.12008.07
219
7
1)
The analog output speed can be changed from „slow output“ to „fast output“ by the operation software and
vice versa.
BM4-F-AIO-
01
02
03
04
No of inputs
2
No of I/O assignments input
2
Resolution
10 bit / 12 bit
16 bit
12 bit
16 bit
Type
Differenzeingang
Input resistance
ca. 50 k
ca. 100
Max. input current
200 µA
20 mA
Min. input current
4 mA
Sampling rate inputs, one input used
125 µs
Sampling rate inputs, both input used
250 µs
Analog input voltage
-10 V bis +10 V
2 V
No of outputs
2
1)
No of I/O assignments output
2
Max. output current
1 mA
Resolution
8 bit
16 bit
12 bit
16 bit
Update rate fast outputs
125 µs
Update rate slow outputs
8 ms
Short-circuit current capability output
limited short-circuit proof (max. 10 s)
Analog output voltage
-10 V bis +10 V