Baumüller accessories
Instruction handbook
b maXX
BM4400, BM4600, BM4700
Document No.: 5.12008.07
Baumüller Nürnberg GmbH
308
11.5
In case the cable is produced self, please use the instructions stated below:
1
Use the following materials:
m
Cable: LIYCY 5 x (2 x 0.14) + 2 x 0.5 mm, Cu braiding with at least 85% opt. overlap
m
D-sub connector. 15-pin, male
m
Circular connector: 12-pin, female (e.g. Interconnectron)
2
Connect the cable shield with the cabinet of the circular connector and with the shield
of the D-sub connector
Figure 109:
Cable connectors, 12-wire
NOTE
The cable connector must be produced according to the illustration which is shown above!
In case there is another assignment of the pins, the cable will not operate and defects as well
as at the encoder module and also at the encoder can appear!