Installation
Instruction handbook
b maXX
BM4400, BM4600, BM4700
Document No.: 5.12008.07
221
7
1)
Unlike DIO/FIO-01 inside DIO/FIO-11 the contact „ground external“ is
not
connected to PE.
2)
On tripping, there appears an error message on the controller.
3)
Limit the current to 2.5 A. (Due to this also UL 508 C with a maximum current of 4 A will be considered).
DIO-01 / DIO-11
1)
FIO-01 / FIO-11
1)
Power supply
24 V (19 to 28 V)
3)
Current consumption (24 V)
2.0 A
Current consumption (internal)
max. 50 mA
No. of inputs
4
Evaluation inputs
edges (2 inputs can be used for writing on one parameter)
Number of I/O-linking groups input
4
Max. input current
2 mA
5 mA
(Typical) transit time delay, input side
4 ms
10 µs
Digital input voltage
0 (LOW) = 0 to 5 V;
1 (HIGH) = 12 to 28 V
Number of outputs
4
Number of I/O-linking groups output
4
Max. output current
0.5 A
Resistance to short circuiting at outputs
yes, limited by current with tripping
2)