Troubleshooting and fault correction
Instruction handbook
b maXX
BM4400, BM4600, BM4700
Document No.: 5.12008.07
247
9
P0211
Error drive management
P0212
Error data set management
Error No.
Meaning
Reaction
Troubleshooting
160
Timeout communication
adjustable Remove the timeout of the Proprog communication
161
Timeout BACI
adjustable Remove the timeout of the BACI communication option
module
162
Timeout cyclic communication
adjustable Remove the timeout of the Cyclic communication:
163
Timeout service data
adjustable
164
Field bus error
adjustable Check the field bus communication
165
Controller not synchronous to external signal
adjustable Set the Sync offset and/or Sync tolerance
166
Error at brake control
IS
Check the wiring and the function of the brake
167
No release of holding brake when starting the
drive
IS
Check the holding brake
168
No closing of holding brake at stopping of drive
adjustable
169
Error holding brake status (cyclic monitoring)
adjustable
170
Error holding brake lining
adjustable
171
Error initialize holding brake
IS
Check, if there is a DIO module, if it is in the correct
slot and if it is correctly parameterized (also see
P0883)
172
Error holding brake: holding torque not reached
IS
Ensure that the torque limits are not set too small
|P1402| < Min (|P1036|, |P1037|, |P1038|)
173 to 175
reserved, not assigned = 0
Error No.
Meaning
Reaction
Troubleshooting
176
EEPROM copy error
adjustable Copy the data set once more
177
Write timeout EEPROM
adjustable The data in the EEPROM are invalid, please safe all
data sets
178
Checksum error EEPROM
IS
EEPROM faulty or described faulty
179
No boot data set
IS
The data in the EEPROM are invalid, please safe all
data records
180
Incompatible software
IS
181
There is no data set
adjustable
182
Checksum error im PSI module
adjustable PSI EEPROM faulty or write faulty
183
PSI is reset
adjustable Please save all data records
184
PSI data invalid
adjustable The data in the PSI are invalid, please save all data
sets
185
Autotuning tables invalid.
adjustable Restart autotuning
186
A/D correction table invalid
adjustable Replace the controller cartridge
187
EEPROM is reset
IS
The data in the EEPROM is reset, please safe all data
records
188 to 191
reserved, not assigned = 0