Safe stop
Instruction handbook
b maXX
BM4400, BM4600, BM4700
Document No.: 5.12008.07
335
E
Shutdown
path B
Pulse enable at BM4000 controller LC3
The safety function pulse enable is active, if no voltage is applied to the input terminals
(X3-3/5). The pulses for IGBT control are inhibited.
24 V must be applied to the available terminals (X3-3/5), to deactivate the safety function.
C.2.2.2 Sequence diagram
The starting and the shutdown sequence of the release signals and of the safety relay must be
considered, in order to assure a faultless operation of the drive.
Figure 111:
Sequence diagram of 1 or 2 safety relays
NOTE
The safety function must be checked, before commissioning the machine, in which
the BM4000, with the safety function STO is installed. For this purpose a protective
function must be enabled (for example door contact). The motor must be with zero-
torque.
Содержание b maxx BM4400
Страница 137: ...Design and Operation Instruction handbook b maXX BM4400 BM4600 BM4700 Document No 5 12008 07 137 of 358 4 ...
Страница 322: ...Instruction handbook b maXX BM4400 BM4600 BM4700 Document No 5 12008 07 Baumüller Nürnberg GmbH 322 of 358 A ...
Страница 358: ...Instruction handbook b maXX BM4400 BM4600 BM4700 Document No 5 12008 07 Baumüller Nürnberg GmbH 358 of 358 Notes ...
Страница 359: ......