Design and Operation
Instruction handbook
b maXX
BM4400, BM4600, BM4700
Document No.: 5.12008.07
119
4
Slots
In slots of the controller unit functional- or optional modules are plugged, which extend
the functionality of the controller unit.
Each slot is identified by a code letter.
Dependable of the existing controller unit version on your device you can retrofit optional
plug-in modules (functional modules and optional modules).
1-
, 2- and 3
-row
ed
A
The controller communicates via a functional module bus with plug-in modules in
these slots.
Slot D can initiate an interrupt. Therewith slot D is particularly suitable for measur-
ing modules.
Optional modules can
not
be inserted into these slots.
B
C
D
E
F
Controller module, not exchangeable with RS232 or Ethernet interface
2-
and 3-
rowed
G
The controller communicates via the BACI-bus with plug-in modules in these slots.
Function modules can
not
be inserted into these slots.
H
3-r
owed
J
The controller communicates via the BACI-bus with plug-in modules in these slots.
Function modules can
not
be inserted into these slots.
K
L
M
NOTICE!
Plug-in module, which has not been manufactured from Baumüller Nürnberg
GmbH.
Modules of other manufacturers can damage/destroy the device.
Only use BM4-F-XXX- and BM4-O-XXX-plug-in modules.