Software
6.2 Configuration in Automation Studio
6.2.1 Standard options
Standard options
The standard options for configuring the Power Panel C80 in Automation Studio are described in Automation Help:
➯
Programming / Editors / Configuration editors / Hardware configuration / CPU configuration / SG4
6.2.2 Terminal configuration
The terminal (for mapp View or VC4-based HMI appli-
cations) is also configured within the CPU configuration
in Automation Studio:
6.2.2.1 Startup
The behavior during device startup is defined with the options in group "Terminal configuration / Startup":
Parameter
Setting/Description
Display AR status
Default setting: on
The terminal can display the status of the controller (Automation Runtime) on the screen during startup:
Selection
Description
off
The AR status is not displayed.
on
The AR status is displayed.
If the controller does not change to mode RUN after startup, a button will appear at the bottom right of the screen to open
"System Diagnostics Manager" (SDM).
For additional information about "System Diagnostics Manager", see Automation Help.
Display logo
Default setting: off
This option defines whether a boot logo (static and/or animated) is displayed while establishing the connection between
the terminal and web server (address specified under
with option "URL of application"):
Selection
Description
off
A logo is not displayed.
on
A logo is displayed.
Information:
To transfer logos from Automation Runtime to the terminal, the TFTP server must be enabled in the
CPU configuration.
Power Panel C80 User's manual V1.02
47