Troubleshooting 6-1
MN1902
6.1 Introduction
This section explains common problems that may be encountered, together with possible
solutions.
6.1.1 Problem diagnosis
If you have followed all the instructions in this manual in sequence, you should have few
problems installing the FlexDrive
II
. If you do have a problem, read this section first.
In WorkBench v5, use the Error Log tool to view recent errors and then check the help file.
If you cannot solve the problem or the problem persists, the SupportMe
t
feature can be used.
6.1.2 SupportMe
t
feature
The SupportMe
t
feature (on the Help menu) can be used to e-mail information to the Baldor
representative from whom you purchased the equipment. If required, you can choose to add
your program files as attachments. WorkBench v5 will automatically start up your e-mail
program and begin a new message, with comprehensive system information and selected
attachments already in place. You can add any additional message of your own and then send
the e-mail. The PC must have email facilities to use the SupportMe
t
feature. If you prefer to
contact Baldor technical support by telephone or fax, contact details are provided at the front
of this manual. Please have the following information ready:
H
The serial number of your FlexDrive
II
.
H
Use the Help, SupportMe menu item in WorkBench v5 to view details about your system.
H
The catalog and specification numbers of the motor that you are using.
H
Give a clear description of what you are trying to do, for example trying to establish
communications with WorkBench v5 or trying to perform fine-tuning.
H
Give a clear description of the symptoms that you can observe, for example the Status
display, error messages displayed in WorkBench v5, or the current value of any of the
Mint error keywords
AXISERROR
,
AXISSTATUS
,
INITERROR
,
MISCERROR
and
DRIVEERROR
.
H
The type of motion generated in the motor shaft.
H
Give a list of any parameters that you have setup, for example the motor data you
entered/selected in the Commissioning Wizard, the gain settings generated during the
tuning process and any gain settings you have entered yourself.
6.1.3 Power-cycling the FlexDrive
II
The term “Power-cycle the FlexDrive
II
” is used in the Troubleshooting sections. On models
with a customer supplied 24V supply, remove the 24V supply, wait for the FlexDrive
II
to power
down completely (all Status LED segments will turn off), then re-apply the 24V supply.
On models with an internally generated 24V supply, remove the AC power supply, wait for the
FlexDrive
II
to power down completely (all Status LED segments will turn off), then re-apply AC
power.
6
Troubleshooting
6
Содержание Flex+DriveII
Страница 1: ...FlexDriveII Flex DriveII Servo Controls SERVO DRIVE Installation Manual 10 02 MN1902...
Страница 2: ......
Страница 14: ...2 4 Introduction MN1902...
Страница 68: ...4 20 Input Output MN1902...
Страница 80: ...5 12 Operation MN1902...
Страница 98: ...7 12 Specifications MN1902...
Страница 106: ...A 8 Accessories MN1902...
Страница 122: ...Index MN1902...
Страница 124: ...Comments MN1902 Thank you for taking the time to help us...
Страница 125: ......