4-14 Input / Output
MN1902
4.4.3 Serial port - X6
Location
Connector X6
Pin RS232 name
RS485 / RS422 name
1
(NC)
(NC)
2 RXD
RX- (input)
3 TXD
TX- (output)
4
(NC)
(NC)
5 0V GND
0V DGND
6
(NC)
(NC)
7 RTS
TX+ (output)
8 CTS
RX+ (input)
9
(
Do not connect! See caution below
)
Description
RS232 or RS485 / RS422 connections on a single
9-pin female D-type connector
Connector X6 is a 9-pin male D-type connector. This port is configurable as either RS232 or
4-wire RS422 / RS485, using front panel DIP switch number 10 (see section 3.9.6). The Mint
keyword
SERIALBAUD
is used to configure the port and is explained in the Mint help file. See
also sections 4.4.4 and 4.4.5. The port is fully ESD protected to IEC 1000-4-2 (15kV).
When using RS485 / RS422 mode, front panel DIP switch number 6 may be used to connect
an internal 120
Ω
termination resistor between the RX+ and RX- signals. Switch 6 should
remain in the Off position when using RS232.
CAUTION
: Pin 9 is used to carry +8V for powering certain Baldor keypad peripherals.
Ensure that pin 9 is not connected to earth/ground or to equipment that
could be damaged by the +8V supply.
1
5
6
9
Содержание Flex+DriveII
Страница 1: ...FlexDriveII Flex DriveII Servo Controls SERVO DRIVE Installation Manual 10 02 MN1902...
Страница 2: ......
Страница 14: ...2 4 Introduction MN1902...
Страница 68: ...4 20 Input Output MN1902...
Страница 80: ...5 12 Operation MN1902...
Страница 98: ...7 12 Specifications MN1902...
Страница 106: ...A 8 Accessories MN1902...
Страница 122: ...Index MN1902...
Страница 124: ...Comments MN1902 Thank you for taking the time to help us...
Страница 125: ......