4-4 Input / Output
MN1902
4.2.2 Relay output - X3
Location
Connector X3, pins 4 (+) & 5 (-)
Name
General purpose relay
Mint keyword
RELAY
Description
Relay switch contacts controlled by Mint, rated at 1A,
30VDC. Normally closed.
Update interval: Immediate
The factory preset assignment for the relay is as the global error output signal
(see the Mint keyword
GLOBALERROROUTPUT
). When an error occurs the relay
is de-energized and the normally closed relay contacts are opened.
When the error is cleared, the relay is re-energized and the contacts are
closed. The relay can be also be controlled directly by the Mint keyword
RELAY
.
When the relay is de-energized (
RELAY=_off
) the contacts open.
An axis can use the relay as its drive enable output signal. This can be configured in
WorkBench v5 or by using the Mint keyword
DRIVEENABLEOUTPUT
. This prevents
access by
RELAY
, but means that the relay can be used to monitor the state of the
DRIVEENABLE
keyword. See the Mint help file for details.
Internal relay
FlexDrive
II
Relay +
Pin 4
Relay -
Pin 5
Control
circuitry
Figure 25 - Relay contact outputs
4
5
Содержание Flex+DriveII
Страница 1: ...FlexDriveII Flex DriveII Servo Controls SERVO DRIVE Installation Manual 10 02 MN1902...
Страница 2: ......
Страница 14: ...2 4 Introduction MN1902...
Страница 68: ...4 20 Input Output MN1902...
Страница 80: ...5 12 Operation MN1902...
Страница 98: ...7 12 Specifications MN1902...
Страница 106: ...A 8 Accessories MN1902...
Страница 122: ...Index MN1902...
Страница 124: ...Comments MN1902 Thank you for taking the time to help us...
Страница 125: ......