User Manual UMAX030541. Version V1 110-116
Entry Description
Sub-Index
0h
Access
RO
PDO Mapping
Yes
Value Range
-50 to 150 [DegC]
Default Value
No
3.4.66 Object 5031h: Enable Error Detection on Temperature
This write-able object is available to enable faults on temperature measured in the
system. When this object is enabled, objects 5032h-5033h are used to determine fault
triggers and fault clear thresholds. For more information, please refer to Section 1.7.
Object Description
Index
5021h
Name
Enable Error Detection on Temperature
Object Type
VARIABLE
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Access
RW
PDO Mapping
No
Value Range
FALSE; TRUE
Default Value
TRUE (1)
3.4.67 Object 5032h: Over Temperature Threshold
This object is used to set the value at which a temperature fault will trigger if the measured
microcontroller temperature falls above it. If object 5031h is disabled, this value is ignored.
For more information, please refer to Section 1.7.
Object Description
Index
5032h
Name
Over Temperature Threshold
Object Type
VARIABLE
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Access
RW
PDO Mapping
No
Value Range
0…150 (DegC)
Default Value
85 (DegC)