User Manual UMAX030541. Version V1 38-116
•
The module will send the following response (any other response is a failure).
Item
Value
COB-ID
0x7E4
Length
3
Data 0
0x11
(cs=17 for configure node-id)
Data 1
0x00
Data 2
0x00
•
Save the configuration by
sending
the following message:
Item
Value
COB-ID
0x7E5
Length
1
Data 0
0x17
(cs=23 for store configuration)
•
The module will send the following response (any other response is a failure):
Item
Value
COB-ID
0x7E4
Length
3
Data 0
0x17
(cs=23 for store configuration)
Data 1
0x00
Data 2
0x00
•
Set the module state to LSS-operation by
sending
the following message:
(Note, the module will reset itself back to the pre-operational state)
Item
Value
COB-ID
0x7E5
Length
2
Data 0
0x04
(cs=4 for switch state global)
Data 1
0x00
(switches to waiting state)
3.1.1.2
Setting Baudrate
•
Set the module state to LSS-configuration by
sending
the following message:
Item
Value
COB-ID
0x7E5
Length
2
Data 0
0x04
(cs=4 for switch state global)
Data 1
0x01
(switches to configuration state)