User Manual UMAX030541. Version V1 109-116
Object Description
Index
5024h
Name
Hysteresis to Clear Supply Fault
Object Type
VARIABLE
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Access
RW
PDO Mapping
No
Value Range
1V…30V
Default Value
3 (V)
3.4.64 Object 5025h: Enable Power Supply Fault Disables Outputs
This write-able object is available to enable disable on all the outputs when there are
faults on power supply measured in the system. For more information, please refer to
Section 1.7.
Object Description
Index
5025h
Name
Enable Power Supply Fault Disables Outputs
Object Type
VARIABLE
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Access
RW
PDO Mapping
No
Value Range
FALSE; TRUE
Default Value
TRUE (1)
3.4.65 Object 5030h: Processor Temperature Field Value
This read-only object is available for diagnostic feedback purposes. It reflects the
measured processor temperature of the controller. The physical unit for this object is
Celsius.
Object Description
Index
5030h
Name
Processor Temperature Field Value
Object Type
VARIABLE
Data Type
FLOAT32