User Manual UMAX030541. Version V1 73-116
3.4.1 Object 2223h: DO Blink Rate 1 Output Line
This object is used only when an ON/OFF digital output has been specified for a
blinking response by object 2241h DO Polarity. While the DO is commanded ON, it will
blink ON/OFF at the rate specified in this object. The physical unit is milliseconds.
Object Description
Index
2223h
Name
DO Blink Rate 1 Output Line
Object Type
ARRAY
Data Type
UNSIGNED16
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
4
Default Value
4
Sub-Index
1h to 4h (x = 1 to 4)
Description
DOx Blink Rate
Access
RW
PDO Mapping
No
Value Range
0 to 60,000
Default Value
500 [ms]
3.4.2 Object 2240h: DO Digital Range
This object determines if the output is at +5V or +12V when ON. It dose not apply to
other types.
Object Description
Index
2240h
Name
DO Digital Range
Object Type
ARRAY
Data Type
UNSIGNED8
Entry Description
Sub-Index
0h
Description
Largest sub-index supported
Access
RO
PDO Mapping
No
Value Range
4
Default Value
4