Axell D-MBR 3007-3008-PS-NFPA
PRODUCT DESCRIPTION AND USER’S MANUAL
© Axell Wireless Ltd
UMCD00013 Rev 2.2
31
3. Set the System Level parameters:
•
RF Transmission Enable
– disables and enables unit RF transmission. Verify
that it is checked (RF transmission ON).
NOTE: RF transmission can be disabled by the system if the Shut Down mechanism is
enabled and the criteria activated the mechanism is fulfilled.
•
Shut Down Mechanism –
when enabled, the system automatically disables RF
transmission if an excessively high input power (from the BTS side) is detected.
The shut down criteria is valid only after a specific period of time that valid
input power level is exceeded. In that case:
o
RF Transmission Parameter
is unchecked (transmission is OFF)
o
System Mute
alarm (Alarms tab) is generated (RED).
NOTE: If the high input power issue is resolved, then it is necessary to enable RF
transmission by checkmarking the
RF Transmission Enable
parameter. In addition, reset
the
System Mute
alarm (click Ack).
•
Max Composite DL Output Power
– set according to your site requirements
and click
Send
. The
Measured
Composite DL Output Power
is displayed in
the adjacent field. If the composite output power exceeds the defined value, the
Smart-ALC feature begins working.
•
Set the
Max Composite UL Output Power
according to your site
requirements.
NOTE: The Temperature shows the Repeater’s ambient temperature. The
DL Output Threshold
Delta (dB)
shows the delta from DL Output Power, below which the alarm 'Donor power is too
low' is activated.
4. Checkmark
ON
for each filter to be configured. The configuration parameters in that
row will be available.
Downlink Channels
Uplink Channels
Defined BW:
Narrow band (N)
or
Wideband (W)