ZM400 Series Indicators Service Manual
55
6.4
System
6.4.1 Default Values
Each area of the world has different requirements for indicator configuration. The table
below shows all the default values listed for all the different sites covered by the
indicator.
USA
GB
CAN
EU
CHINA
INDIA
Capacity
5000
2500
2500
2500
2500
2500
Division
1
0.5
0.5
0.5
0.5
0.5
Unit of measure
lb
kg
kg
kg
kg
kg
Unit of measure 2
kg
off
off
off
off
off
Cal unit
lb
kg
kg
kg
kg
kg
Cal wt
5000
2500
2500
2500
2500
2500
Zero Range
100
2
2
2
2
2
Over Basis
Percent
Division
Percent
Division
Division
Division
Disp. Update Rate
10
20
10
20
10
10
Separator
decimal
decimal
decimal
comma
decimal
decimal
Date Format
MM-DD-YY
DD-MM-YY
DD-MM-YY
DD-MM-YY
DD-MM-YY
DD-MM-YY
Time Format
12 Hr
24
24
24
24
24
Average
10
10
10
10
10
10
Filter Constant
1
1
1
1
1
1
Filter Threshold
100
50
50
50
50
50
Under Cap. Div.
250
20
250
250
250
250
AZT Time
1
1
1
1
1
1
AZT Div.
3
.25
3
3
3
3
Motion Time
1
1
1
1
1
1
Motion Div.
3
.25
3
3
3
3
Default settings may need to be changed to meet local agency requirements
Содержание ZM401
Страница 1: ...AWT35 501334 Issue AA ZM401 405 Weight Indicators Service Manual original instructions CONFIDENTIAL...
Страница 8: ...8 ZM400 Series Indicators Service Manual...
Страница 116: ...116 ZM400 Series Indicators Service Manual 10 Print formatting...
Страница 130: ...130 ZM400 Series Indicators Service Manual...
Страница 145: ...ZM400 Series Indicators Service Manual 145 13 9 Outline dimensions stainless steel ZM4xx Stainless Steel...
Страница 146: ...146 ZM400 Series Indicators Service Manual 13 10 Outline dimensions panel mount ZM4xx Panel Mount...
Страница 150: ...150 ZM400 Series Indicators Service Manual...
Страница 154: ...154 ZM400 Series Indicators Service Manual WSTAT token 124 Z Zero calibration 41 ZM305 main PC board 142...
Страница 155: ......