110
ZM400 Series Indicators Service Manual
10
Print formatting
3.
To move the string index position to the start of the Tare weight output
(SP character 32), press the
UNITS
key until the display shows …
4.
You need to delete all characters from index position 25 through 36 to remove
the entire Tare weight line. Press and hold the
TARE
key for two seconds to
delete the displayed character. The remaining characters shift to this index
position. Repeatedly press and hold the
TARE
key until the display shows …
5.
This is the start of the Net weight output (SP character 32, see current index
position 37).
6.
Press the
ZERO
key when finished with the edit process to accept these
changes and return to
PrnFt1
display.
7.
Press
TARE
or
F1
until …
SAVE no
is displayed.
8.
Press UNITS …
SAVEYES
is displayed.
9.
Press
ZERO
to save.
After the indicator reboots press the
key to test the results. The following should
be printed:
GROSS
lb
GROSS
lb
Gross 272.04 lb
Net 176.16 lb
At any time during a string edit you can press
F1
to abort the print format editor
without affecting the existing print string. This allows for an ESCAPE if you think you
may have made an error during the editing process.
Содержание ZM401
Страница 1: ...AWT35 501334 Issue AA ZM401 405 Weight Indicators Service Manual original instructions CONFIDENTIAL...
Страница 8: ...8 ZM400 Series Indicators Service Manual...
Страница 116: ...116 ZM400 Series Indicators Service Manual 10 Print formatting...
Страница 130: ...130 ZM400 Series Indicators Service Manual...
Страница 145: ...ZM400 Series Indicators Service Manual 145 13 9 Outline dimensions stainless steel ZM4xx Stainless Steel...
Страница 146: ...146 ZM400 Series Indicators Service Manual 13 10 Outline dimensions panel mount ZM4xx Panel Mount...
Страница 150: ...150 ZM400 Series Indicators Service Manual...
Страница 154: ...154 ZM400 Series Indicators Service Manual WSTAT token 124 Z Zero calibration 41 ZM305 main PC board 142...
Страница 155: ......