52
ZM400 Series Indicators Service Manual
6
ADMIN level menus
diV
Use this to choose to base over/
under capacity on number of
divisions.
o-LoAd
This stands for overload. Once you’ve picked the
basis for an over capacity condition, use this item
to set the value that triggers the overload
condition.
u-LoAd
This stands for underload. Use this item to set the
value that triggers the underload condition.
g-ZEro
Use this to configure the gross zero band. This is a parameter
used to perform the tare clear function and set the Return to
Zero range for Autoprint, Acccumulate, Checkweighing,
Counting and Batch functions. You can enter a value between
0 and 10000 divisions.
6.3.9 2,3,Range
The indicator can be setup for dual or triple ranging operation using multi-range or
multi-interval type division size switching
CAP 1
CAP 1 is used for both dual and triple range operation. In dual range
operation (and increasing weight) values between 0 and
CAP 1
will use
DiV 1
as the division size and values above
CAP 1
will use the division size
entered in
CAP 2
CAP 2 is used for triple ranging operation only. In triple range operation
(and increasing weight) values between 0 and the
CAP 1
will use
DiV 1
as
the division size, values between
CAP 1
and
CAP 2
will use
DiV 2
as the
division size, and values above
CAP 2
will use the division size entered in
.
DIV 1
This is the division size for the 1st weight range.
DIV 2
This is the division size for the 2nd weight range.
tYPE
Use this to choose between Multi Range or Multi Interval. The Type setting
determines the condition for switching to a new division size when weight
is removed.
M.rAngE
Multi-range - the division size will change as it enters a new weight range
on increasing weight but will not change back to the smaller division size
until the display returns to Zero. This is the default setting.
CAP 1
CAP 2
Div 1
Div 2
Type
M.range
M.intrvl
2,3,Range
0.000001
500
500
0.000001
Key in
CAP 1
capacity
Key in
CAP 2
capacity
to
to
Содержание ZM401
Страница 1: ...AWT35 501334 Issue AA ZM401 405 Weight Indicators Service Manual original instructions CONFIDENTIAL...
Страница 8: ...8 ZM400 Series Indicators Service Manual...
Страница 116: ...116 ZM400 Series Indicators Service Manual 10 Print formatting...
Страница 130: ...130 ZM400 Series Indicators Service Manual...
Страница 145: ...ZM400 Series Indicators Service Manual 145 13 9 Outline dimensions stainless steel ZM4xx Stainless Steel...
Страница 146: ...146 ZM400 Series Indicators Service Manual 13 10 Outline dimensions panel mount ZM4xx Panel Mount...
Страница 150: ...150 ZM400 Series Indicators Service Manual...
Страница 154: ...154 ZM400 Series Indicators Service Manual WSTAT token 124 Z Zero calibration 41 ZM305 main PC board 142...
Страница 155: ......