ZM400 Series Indicators Service Manual
59
6.4
System
FFALL 1
Activate this to see the free fall 1 value. Free fall is like preact.
This is the calculated amount of material that will fall on the
scale base on the current flow rate.
Fut gr 1
Activate this to see the future gross value (#1). This
represents a predicted gross weight calculated by multiplying
the current rate by the free fall time and adding the result to
the current gross weight:
Future Gross = Rate X Free Fall + Gross
Fut nt 1
Activate this to see the future net value (#1). This represents
a predicted net weight calculated by multiplying the current
rate by the free fall time and adding the result to the current
net weight:
Future Net = Rate X Free Fall + Net
FFALL 2
Activate this to see the free fall 2 value. Free fall is like preact.
This is the calculated amount of material that will fall on the
scale base on the current flow rate.
Fut gr 2
Activate this to see the future gross value (#2). This
represents a predicted gross weight calculated by multiplying
the current rate by the free fall time and adding the result to
the current gross weight:
Future Gross = Rate X Free Fall + Gross
Fut nt 2
Activate this to see the future net value (#2). This represents
a predicted net weight calculated by multiplying the current
rate by the free fall time and adding the result to the current
net weight:
Future Net = Rate X Free Fall + Net
PcWt 1X
Activate this to see the average piece weight x 1000. The
average piece weight x 1000 parameter represents the
average weight of 1000 pieces as calculated during the
sampling routine.
PEr Acc
Activate this to see the percent accuracy value. The percent
accuracy parameter represents the minimum accuracy
achieved during the last sample routine. Only one percent
accuracy parameter is maintained for all enabled scales.
LSt SMP
Activate this to see the Last sample size value. The last
sample size parameter represents the number of pieces used
during the last sample routine to determine the current
average piece weight. Only one last sample size parameter is
maintained for all enabled scales.
Содержание ZM401
Страница 1: ...AWT35 501334 Issue AA ZM401 405 Weight Indicators Service Manual original instructions CONFIDENTIAL...
Страница 8: ...8 ZM400 Series Indicators Service Manual...
Страница 116: ...116 ZM400 Series Indicators Service Manual 10 Print formatting...
Страница 130: ...130 ZM400 Series Indicators Service Manual...
Страница 145: ...ZM400 Series Indicators Service Manual 145 13 9 Outline dimensions stainless steel ZM4xx Stainless Steel...
Страница 146: ...146 ZM400 Series Indicators Service Manual 13 10 Outline dimensions panel mount ZM4xx Panel Mount...
Страница 150: ...150 ZM400 Series Indicators Service Manual...
Страница 154: ...154 ZM400 Series Indicators Service Manual WSTAT token 124 Z Zero calibration 41 ZM305 main PC board 142...
Страница 155: ......