HEATER SETTING
HEATER DISPLAY ON
HEATER MODE AUTO
TEMPERATURE SET 33
℃
BACK
EXIT
Screen 28: Heater Setting
Option
Value
Explanation
HEATER DISPLAY
ON/OFF
This switches the heater status display on and off. The
message “
HEATER
” will appear when the heater is on.
HEATER MODE
AUTO
Heater operating mode: when set to ”AUTO”, the heater is
operated when the outside temperature is lower than the
setting made in the following menu.
OFF
The heater is always off.
ON
The heater is always on.
TEMPERATURE SET
-99 ~ +99
Temperature threshold in °C under which the heater is
activated. Recommended values 18 - 20 °C
Table 23
30 / 35
4.3.4.6. CRUISE SUBMENU
CRUISE
DWELL TIME<SECS> 7
PRESET LIST 1
1 ON 0 OFF
1 2 3 4 5 6 7 8 9 0
0 1 1 0 0 1 0 1 1 1
BACK
EXIT
Screen 29: Cruise
The
CRUISE
function is used to make the camera run a cycle consisting of up to 30 preset positions.
This menu item is used to enable each of the preset positions used in the cruise cycle.
For the cruise cycle to be effective, the preset positions must be actually stored.
Option
Value
Explanation
DWELL TIME <SECS>
5 ~ 250
Duration (in seconds) of the dwelling time on each presetting.
PRESET LIST
1 ~ 3
Value 1 selects the first group of Presets from 1 to 10, value 2
selects the second group from 11 to 20, value 3 the third
group from 21 to 30.
The following 10 digits (1/10) are used to switch the
corresponding preset in the corresponding ten (1-10, 11-20,
21-30) either on or off (1=
ON
; 0=
OFF
).
Table 24
4.3.4.7. TRACKING SETTING SUBMENU