The camera has 4 alarm inputs and 2 alarm outputs.
The actions defined by the user may be associated to an alarm.
Option
Value
Explanation
ALARM NUMBER
1 ~ 4
This option allows selecting one of the 4 alarm inputs.
SEQUENCE (SECS)
1 ~ 250
Duration time (in seconds) of the action related to each alarm
when several alarms occur at the same time.
ALARM SETTINGS
This submenu contains the alarm management programming
(see below).
CLEAR SETTINGS
This submenu is used to delete the alarm programming (see
below).
Table 16
ALARM SETTINGS submenus
This includes the operations needed to program the alarms.
ALARM SETTINGS
ALARM NUMBER 1
ALARM ACTION NONE
ACTIVATE AUX OFF
ALARM CONTACT OFF
BACK
EXIT
Screen 20: Alarm Settings
Option
Value
Explanation
ALARM NUMBER
1 ~ 4
This option allows selecting one of the 4 alarm inputs.
ALARM ACTION
NONE
No action occurs during the alarm.
PRESET
The camera goes to the corresponding presetting following
the alarm (corresp ndence is fixed: Alarm 1 - Preset 1; Alarm
o
2 - Preset 2, etc.).
PATTERN
The alarm performs the corresponding pattern following the
alarm (correspondence is fixed: Alarm 1 - Pattern 1; Alarm 2 -
Pattern 2; etc.)
AUTOSCAN
The camera performs an auto scan after the alarm: the
camera performs a 360 horizontal scan operation.
RANDOM SCAN
The camera performs a random scan after the alarm: the
camera performs a random 360° scan pausing for
approximately 2” every 142°.
FRAME SCAN
The camera performs a frame scan after the alarm: the
horizontal scan is performed in the
SET SCAN
limits.
CRUISE
The camera performs a cruise after the alarm: the camera
runs a cycle of up to 30 preset positions.
TRACKING
The camera performs a tracking operation after the alarm,
starting from the preset position associated with the alarm.
ALARM AUX
OFF
No action occurs after the alarm.
AUX1
AUX1
output is activated following the alarm: e.g. a siren.
AUX2
AUX2
output is activated following the alarm: e.g. a blinker.
ALARM CONTACT
ON/OFF
Alarm output polarity: normally open (
ON
) or normally closed
(
OFF
).
The circuit will open to generate an alarm if it is “
NC
” and will
close if it is “
NO
”.
Table 17