![Autonics AiC-D-20LA Скачать руководство пользователя страница 99](http://html1.mh-extra.com/html/autonics/aic-d-20la/aic-d-20la_user-manual_3022257099.webp)
11 Driver Function
ⓒ Copyright Reserved Autonics Co., Ltd.
99
11
Driver Function
11.1
General Drive
11.1.1
Fixed Pulse and Continuous Pulse Drive
Drive pulse output on each axis is basically in +/- directions by drive instruction of a fixed or
continuous pulse.
11.1.1.1
Fixed Pulse Drive
Fixed pulse drive is used to move something a fixed amount. It operates fixed speed or
acceleration/deceleration drive for a specified number of output pulses.
Acceleration/Deceleration fixed pulse drive starts to reduce speed when remaining output
pulse is less than the pulse used for acceleration. It ends drive when it finishes generating
pulse, as shown in the image below.
Absolute position movement and relative position movement
: There are absolute position movement and relative position movement.
These are fixed pulse drive.