11 Driver Function
108
© Copyright Reserved Autonics Co., Ltd.
11.2.3
Stop Current
When it stops, set the stop current supplied at the motor phase to decrease motor heat and
current consumption.
Factory default is 50% of max. run current. It is available to set at the parameter.
Parameter
Setting range
Unit
Unit value
factory default
Stop Current
20 to 100
%
1
50
11.2.4
Stop Current Fix
Set the stop current control method; Enable, Disable (factory default).
Enable: Fixed stop current
: It maintains stop current as the set value at the parameter.
Disable: Setting stop current
: It adjusts by stop current load and it is able to reduce over heat of motor.
11.2.5
Speed Filter
It is available to set motor drive response according to the instruction at the parameter.
Set the speed filter value for time delay between the command position and motor. It is able
to drive softly even though load changing or disturbance occurs.
Parameter
Setting
Value (msec)
Speed Filter
0
Disable
1
2
2
4
3
6
4
8
5
10
6
20
7
40
8 (factory
default)
60
9
80
10
100
11
120
12
140
13
160
14
180
15
200
Содержание AiC-D-20LA
Страница 2: ......
Страница 19: ...1 Product Overview Copyright Reserved Autonics Co Ltd 19...
Страница 34: ...3 Dimensions 34 Copyright Reserved Autonics Co Ltd...
Страница 40: ...5 Connection 40 Copyright Reserved Autonics Co Ltd 5 Connection 5 1 Standard Type...
Страница 41: ...5 Connection Copyright Reserved Autonics Co Ltd 41 5 2 Built in Brake Type...
Страница 45: ...6 Characteristics Copyright Reserved Autonics Co Ltd 45...
Страница 116: ...Dimensions or specifications on this manual are subject to change and some models may be discontinued without notice...