![Autonics AiC-D-20LA Скачать руководство пользователя страница 94](http://html1.mh-extra.com/html/autonics/aic-d-20la/aic-d-20la_user-manual_3022257094.webp)
10 Program Instructions
94
© Copyright Reserved Autonics Co., Ltd.
Continuation
: It drives continuously removing acceleration/deceleration time of each step at
program
mode.
Set the use/not use continuation.
Enable=Use continuation
Disable=Not use continuation
Step
Acceleration
time (ms)
Deceleration
time (ms)
Start drive speed
(pps)
Max. drive speed
(pps)
1
1,000
0
500
5,000
2
1,000
0
5,000
10,000
3
1,000
0
10,000
20,000
4
0
1,000
7,000
20,000
5
0
1,000
0
7,000
For the step with acceleration, set deceleration time as 0ms.
For the step with deceleration, set acceleration time as 0ms.
10.1.3
HOM (home search)
It is for home search according to the set parameter of Home Search Mode (Home search
mode).
Instruction
DATA
HOM
instruction
For more information, refer to the ‘9.5Home search’ .
Содержание AiC-D-20LA
Страница 2: ......
Страница 19: ...1 Product Overview Copyright Reserved Autonics Co Ltd 19...
Страница 34: ...3 Dimensions 34 Copyright Reserved Autonics Co Ltd...
Страница 40: ...5 Connection 40 Copyright Reserved Autonics Co Ltd 5 Connection 5 1 Standard Type...
Страница 41: ...5 Connection Copyright Reserved Autonics Co Ltd 41 5 2 Built in Brake Type...
Страница 45: ...6 Characteristics Copyright Reserved Autonics Co Ltd 45...
Страница 116: ...Dimensions or specifications on this manual are subject to change and some models may be discontinued without notice...