Mounting Direction of Motor
Motor can be mounted in any directions-facing up, facing down and side ways. No matter
which direction motors to be mounted, be sure not to apply overhung or thrust load on the
shaft.
Refer to the table below for allowable shaft overhung load / thrust load.
Motor size
The distance from the shaft in front (mm),
Allowable overhung load [kgf (N)]
Allowable
thrust
load
D=0
D=5
D=10
D=15
Frame size
42mm
2 (20)
2.6 (25)
3.5 (34)
5.3 (52)
Below
motor
weight
Frame size
56mm
5.5 (54)
6.8 (67)
9.1 (89)
13.3 (130)
Frame size
60mm
Do not apply excessive force on motor cable when mounting motors.
Do not forcibly pull or insert the cable. It may cause poor connection or disconnection of the
cable.
In case of frequent cable movement required application, proper safety countermeasures
must be ensured.
Содержание AiC-D-20LA
Страница 2: ......
Страница 19: ...1 Product Overview Copyright Reserved Autonics Co Ltd 19...
Страница 34: ...3 Dimensions 34 Copyright Reserved Autonics Co Ltd...
Страница 40: ...5 Connection 40 Copyright Reserved Autonics Co Ltd 5 Connection 5 1 Standard Type...
Страница 41: ...5 Connection Copyright Reserved Autonics Co Ltd 41 5 2 Built in Brake Type...
Страница 45: ...6 Characteristics Copyright Reserved Autonics Co Ltd 45...
Страница 116: ...Dimensions or specifications on this manual are subject to change and some models may be discontinued without notice...