Standard
RLL
Instructions
5--53
Standard RLL Instructions
Accumulator Logic Instructions
DL105 PLC User Manual, 3rd Edition
K aaa
ANDD
The And Double is a 32 bit instruction that
logically ands the value in the
accumulator with two consecutive
V--memory locations or an 8 digit (max.)
constant value (Aaaa). The result
resides in the accumulator. Discrete
status flags indicate if the result of the
And Double is zero or a negative number
(the most significant bit is on).
Operand Data Type
DL130 Range
aaa
V--memory
V
All (See page 4--29)
Constant
K
0--FFFFFFFF
Discrete Bit Flags
Description
SP63
Will be on if the result in the accumulator is zero
SP70
Will be on is the result in the accumulator is negative
NOTE:
The status flags are only valid until another instruction that uses the same
flags is executed.
In the following example, when X1 is on, the value in V2000 and V2001 will be loaded
into the accumulator using the Load Double instruction. The value in the
accumulator is anded with 36476A38 using the And double instruction. The value in
the accumulator is output to V2010 and V2011 using the Out Double instruction.
AND 36476A38
Handheld Programmer Keystrokes
LDD
V2000
X1
Load the value in V2000 and
V2001 into the accumulator
ANDD
K36476A38
AND the value in the
accumulator with
the constant value
36476A38
OUTD
V2010
Copy the value in the
accumulator to V2010 and
V2011
0 0 1 0 1 0 0 0 0 1 1 1 1 0 1 0
0 0 1 0 1 0 0 0 0 0 1 1 1 0 0 0
0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0
V2000
2 8 7 A
0 0 0 1 0 1 0 0 0 1 0 0 0 1 1 0
0 1 0 1 0 1 0 0 0 1 1 1 1 1 1 0
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
Acc.
Acc.
Acc.
V2010
2 8 3 8
V2001
5 4 7 E
V2011
1 4 4 6
0 1 0 1 0 1 0 0 0 1 1 1 1 1 1 0
0 0 1 0 1 0 0 0 0 1 1 1 1 0 1 0
0 1 1 0 1 0 1 0 0 0 1 1 1 0 0 0
0 0 1 1 0 1 1 0 0 1 0 0 0 1 1 1
Direct
SOFT
STR
$
SHFT
ANDST
L
3
D
SHFT
OUT
GX
3
D
SHFT
3
D
AND
V
SHFT
3
D
8
I
3
D
SHFT
SHFT
JMP
K
0
A
3
D
6
G
4
E
7
H
6
G
ENT
1
B
ENT
2
C
0
A
1
B
0
A
ENT
2
C
0
A
0
A
ENT
0
A
And Double
(ANDD)
Содержание DL105
Страница 2: ...DL105 PLC User Manual Manual Number D1 USER M...
Страница 308: ...1B DL105 Error Codes In This Appendix Error Code Table...
Страница 314: ...1C Instruction Execution Times In This Appendix Introduction Instruction Execution Times...
Страница 324: ...1D Special Relays In This Appendix DL105 PLC Special Relays...
Страница 327: ...1E PLC Memory In This Appendix DL105 PLC Memory...
Страница 329: ...1F European Union Directives CE In This Appendix European Union EU Directives Basic EMC Installation Guidelines...