K
LDF
A aaa
The Load Formatted instruction loads
1--32 consecutive bits from discrete
memory locations into the accumulator.
The instruction requires a starting location
(Aaaa) and the number of bits (Kbbb) to be
loaded. Unused accumulator bit locations
are set to zero.
Operand Data Type
DL130 Range
A
aaa
bbb
Inputs
X
0--11
----
Outputs
Y
0--7
----
Control Relays
C
0--377
----
Stage Bits
S
0--377
----
Timer Bits
T
0--77
----
Counter Bits
CT
0--77
----
Special Relays
SP
0--117 540--577
----
Constant
K
----
1--32
Discrete Bit Flags
Description
SP76
on when the value loaded into the accumulator by any instruction is zero.
NOTE:
Two consecutive Load instructions will place the value of the first load
instruction onto the accumulator stack.
In the following example, when C0 is on, the binary pattern of C10--C16 (7 bits) will
be loaded into the accumulator using the Load Formatted instruction. The lower 7
bits of the accumulator are output to Y0--Y6 using the Out Formatted instruction.
0
A
7
H
ENT
Handheld Programmer Keystrokes
LDF
C10
K7
C0
Load the status of 7
consecutive bits (C10--C16)
into the accumulator
OUTF
Y0
K7
Copy the value from the
specified number of bits in
the accumulator to Y0 -- Y6
K7
C10
Location
Constant
0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
Acc.
K7
Y0
Location
Constant
C10
C11
C12
C13
C14
C15
C16
OFF
ON
ON
ON
OFF
OFF
OFF
Y0
Y1
Y2
Y3
Y4
Y5
Y6
OFF
ON
ON
ON
OFF
OFF
OFF
The unused accumulator bits are set to zero
Direct
SOFT
STR
$
SHFT
ENT
2
C
0
A
SHFT
ANDST
L
3
D
5
F
SHFT
2
C
1
B
0
A
7
H
ENT
OUT
GX
SHFT
5
F
Load
Formatted
(LDF)
Содержание DL105
Страница 2: ...DL105 PLC User Manual Manual Number D1 USER M...
Страница 308: ...1B DL105 Error Codes In This Appendix Error Code Table...
Страница 314: ...1C Instruction Execution Times In This Appendix Introduction Instruction Execution Times...
Страница 324: ...1D Special Relays In This Appendix DL105 PLC Special Relays...
Страница 327: ...1E PLC Memory In This Appendix DL105 PLC Memory...
Страница 329: ...1F European Union Directives CE In This Appendix European Union EU Directives Basic EMC Installation Guidelines...