ECOM100 Query DHCP Setting (ECDHCPQ) (IB-734)
ECOM100 Query DHCP Setting will determine if DHCP is enabled in the ECOM100 on a
leading edge transition to the IBox. The DHCP Enabled bit parameter will be ON if DHCP
is enabled, OFF if disabled.
ECDHCPQ Parameters
• ECOM100#: this is a logical number associated with this specific ECOM100 module in the specified
slot. All other ECxxxx IBoxes that need to reference this ECOM100 module must reference this
logical number
• Workspace: specifies a V-memory location that will be used by the instruction
• Success: specifies a bit that will turn on once the instruction is completed successfully
• Error: specifies a bit that will turn on if the instruction is not successfully completed
• DHCP Enabled: specifies a bit that will turn on if the ECOM100’s DHCP is enabled or remain off
if disabled - after instruction query, be sure to check the state of the Success/Error bit state along with
DHCP Enabled bit state to confirm a successful module query
Parameter
DL06 Range
ECOM100#
K
K0-255
Workspace
V
See DL06 V-memory map - Data Words
Success
X,Y,C,GX,GY,B
See DL06 V-memory map
Error
X,Y,C,GX,GY,B
See DL06 V-memory map
DHCP Enabled
X,Y,C,GX,GY,B
See DL06 V-memory map
DS
Used
HPP
N/A
The Workspace parameter is an internal, private
register used by this IBox and MUST BE
UNIQUE in this one instruction and MUST
NOT be used anywhere else in your program.
Either the Success or Error bit parameter will
turn on once the command is complete.
In order for this ECOM100 IBox to function,
you must turn ON dip switch 7 on the
ECOM100 circuit board.