7.3.1
Primary Display – Left Page
7.3.1.1
Update SW Tab
-
Display of progress information during SW updates (flash progress information)
-
Display of status and/or result of the SW update (“success”, “failure” statement or error
information and recommended further steps).
Buttons to:
-
Select the SW to be written into the ECU ( Load Flash Container )
-
Cancel the update process at user request at any time ( Cancel )
7.3.1.2
IQA Tab
-
IQA codes displayed separate for ECU-A and ECU-B (both ECUs must hold the same IQA
codes)
-
Input fields for each cylinder to be able to enter IQA codes into both ECUs either manu-
ally or by using a handheld 2D-DataMatrix scanner
Содержание AE300-Wizard