7.2
Maintenance Mode
This is the standard mode of operation. Suitable for routine diagnostic and maintenance
tasks to be performed by engineers while trouble shooting or servicing the AE300 series en-
gine.
The primary display is parted into two halves called pages. Those pages can be used inde-
pendently of each other to display different information. The left hand page contains the
buttons and data entry fields, while the right hand page will display information gathered
from the EECU. Tabs on the top of each page are to be used to select the type of infor-
mation to be displayed.
7.2.1
Primary Display – Left Page
7.2.1.1
Maintenance Tab
-
ECU connection status (ECU connected/not connected and active/passive)
-
Engine serial number (engine type and serial number)
-
ECU serial number
-
ECU SW version
-
ECU HW version
-
ECU Caution lamp status (on/off)
-
Area to display entries of the “Fault Code Memory” (FCM)
Buttons to:
-
Establish a logical connection to the ECU ( Connect ECU )
-
Terminate a logical connection to the ECU ( Disconnect ECU )
-
Read the contents of the Fault Code Memory ( Read Fault Code Memory )
-
Clear (reset) the Fault Code Memory ( Clear Fault Code Memory )