Load (import) a user defined Live View configuration file ( Load LiveView-Config )
-
Save (export) a user defined Live View configuration file ( Save LiveView-Config )
Check/boxes to:
-
Switch from standard to expert mode to gain access to over 150 internal ECU-signals
-
Enable an auxiliary signal, which might be used on request by Austro Engine support
personal. It allows to select one ECU-internal signal per ECU which is not on the drop-
down list and has to be configured by its hex address.
Drop-down lists to:
-
Define a set of Live View signals to be recorded from each ECU (“ECU A/B Signals”)
-
Select one of 5 predefined measurements for display and recording of relevant Live View
signal sets (“Boost-Pressure-Test”, “PowerLever-Test”, “Propeller Selftest”, “Rail-
Pressure-Test”, “Ca-Cr-Angle-Test”)
7.2.2
Primary Display – Right Page
7.2.2.1
Engine Data-Tab
Real time engine data of both ECUs, updated every 20ms
-
Caution lamp status (on/off)
-
ECU status (active/passive)
-
Voter decision (which ECU should be active as result of the voter decision matrix)
-
Battery voltage
-
Engine performance (currently developed power as a percentage of the maximum power
available, same as indicated on the Garmin G1000)
-
Propeller speed
-
Engine oil pressure
-
Engine oil temperature
-
Gearbox oil temperature
-
Coolant temperature
-
Fuel flow
-
Fuel pressure warning (low fuel pressure warning, same as indicated on the Garmin
G1000)