3.2
Hardware
3.2.1
Computer System
The requirements to the PC Hardware are:
Characteristic
Minimum
Recommended
PC System
Standard x86 desktop PC or laptop system
No. of CPU Cores
1
2 or more
Clock Frequency [GHz]
2
at least 2.8
RAM [GByte]
3
8 or more
HD Space (free)
[MByte]
100
for a full Wizard installation (including .NET Framework, VC++ redistrib-
utable library and HW drivers)
Additional HD Space
[MByte]
~100
(will be a good starting point) for log files and aircraft data
Table 3
Hardware Requirements
Note:
3 GByte RAM are required as a minimum space if no other program is concurrently
running! Otherwise more RAM is necessary.
Note 2:
It is recommended to use a Solid State Disk (SSD).
3.2.2
USB/CAN Adapter
A special USB/CAN adapter (provided with the AE300-Wizard) is required to physically con-
nect to the CAN bus of the EECU. It connects to a USB port (at least USB 2.0) of the PC sys-
tem on one end and provides a CAN bus male connector on the other. Additionally this
adapter also acts as a license dongle to enable the AE300-Wizard in one of two operating
modes defined by the license:
-
AE-order number “IPEH-002021-M CAN-USB Adapter M” to unlock “Maintenance mode”
-
AE-order number “IPEH-002021-QM CAN-USB Adapter QM” to unlock “Qualified mainte-
nance mode”
3.2.3
USB DataMatrix Scanner
A specially programmed DataMatrix scanner is optionally available from Austro Engine to
support scanning of IQA codes from injectors (see chapter “9.1.5 Scanning Injector IQA
Codes” on page 72). This is not a required item, but a recommended one to prevent mis-
reading of IQA codes:
-
Part#”
TBD
” hand held IQA scanner
3.2.4
CAN Extension Cable
It is recommended to use an RS-232 extension cable (female to male connectors) of about
2m (7ft) length for a convenient connection from the USB/CAN adapter of the PC/laptop to
the diagnostic plug in the aircraft cockpit.