Descriptions referring to name plate indications
Type designation
Figure 5: Type designation (example)
1.
Actuator type, size and version
2.
Flange size
Type, size and version
These instructions apply to the following devices types and sizes:
●
Type: SA = Actuators for open-close duty
Sizes and generation: 07.2, 07.6, 10.2, 14.2, 14.6, 16.2
Version: UW = for continuous underwater use
●
Type: SAR = Multi-turn actuators for modulating duty
Sizes and generation: 07.2, 07.6, 10.2, 14.2, 14.6, 16.2
Version: UW = for continuous underwater use
●
Type: AC = AUMATIC actuator controls
Size and generation: 01.2
Order number
The product can be identified using this number and the technical data as well as
order-related data pertaining to the device can be requested.
Please always state this number for any product inquiries.
On the Internet at http://www.auma.com > Service & Support > myAUMA, we offer
a service allowing authorised users to download order-related documents such as
wiring diagrams and technical data (both in German and English), inspection certificate
and the operation instructions when entering the order number.
Actuator serial number
Table 1:
Description of serial number (example of 0520MD12345)
MD12345
20
05
Positions 1+2: Assembly in week = week 05
05
Positions 3+4: Year of manufacture = 2020
20
Internal number for unambiguous product identification
MD12345
Actuator enclosure pro-
tection
IP68-C15: The maximum head of water is 15 m.
Actuator terminal plan
Position 9 after TPA: Position transmitter version
I = MWG (magnetic limit and torque transmitter)
AUMA power class for
switchgear
The switchgear used in the actuator controls (reversing contactors/thyristors) are
classified according to AUMA power classes (e.g. A1, B1, ....). The power class
defines the max. permissible rated power (of the motor) the switchgear has been
designed for. The rated power (nominal power) of the actuator motor is indicated in
kW on the motor name plate. For the assignment of the AUMA power classes to the
nominal power of the motor types, refer to the separate electrical data sheets.
For switchgear without assignment to any power classes, the actuator controls name
plate does not indicate the power class but the max. rated power in kW.
Data Matrix code
When registered as authorised user, you may use our AUMA Assistant App to scan
the Data Matrix code and directly access the order-related product documents without
having to enter order number or serial number.
Figure 6: Link to AUMA Assistant App:
8
SA 07.2-UW – SA 16.2-UW / SAR 07.2-UW – SAR 16.2-UW Control unit: electronic (MWG)
Identification