MP-11x & MP-124
4.
Configure the debug level using the 'Debug Level' parameter.
5.
Under the 'Activity Types to Report ...' group, select the activities to report.
6.
Click
Submit
to apply your changes.
37.3 Configuring Debug Recording
The device enables you to activate debug recording and send debug recording packets to
a defined capturing server. When the debug recording is activated, the device duplicates all
messages that are sent and/or received by it and then sends them to an external IP
address. The debug recording can be done for different types of traffic for example,
RTP/RTCP, T.38, and SIP.
Debug recording is used for advanced debugging when you need to analyze internal
messages and signals. Debug recording is also useful for recording network traffic in
environments where hub or port mirroring is unavailable and for recording internal traffic
between two endpoints on the same device.
Note:
Debug recording is collected only on the device's OAMP interface.
To configure and activate debug recording:
1.
Open the Logging Settings page (
Configuration
tab >
System
menu >
Logging
>
Logging Settings
).
Figure
37-1: Logging Settings Page
2.
Configure the debug capturing server using the 'Debug Recording Destination IP' and
'Debug Recording Destination Port' parameters.
3.
From the 'Debug Recording Status' drop-down list, select
Start
to start the debug
recording or
Stop
to end the recording.
4.
Click
Submit
to apply your changes.
37.4 Filtering Syslog Messages and Debug Recordings
The device can filter Syslog messages and debug recording (DR) packets, sent by the
device to a Syslog server and packet capturing application (such as Wireshark)
respectively. This can be useful to reduce CPU consumption and minimize negative impact
on VoIP performance.
You can configure up to 30 filtering rules, each based on a selected filtering criteria (e.g.,
an IP Group). Each filtering criteria can be configured with a range. For example, you can
filter Syslog messages for IP Groups 1 through 4. For each filter criteria, you can enable or
disable Syslog messages and debug recording.
Debug recording can also be filtered using various filtering criteria such as SIP signaling or
signaling and media.
Содержание MediaPack MP-112
Страница 2: ......
Страница 14: ...User s Manual 14 Document LTRT 65417 MP 11x MP 124 Reader s Notes ...
Страница 21: ...Part I Getting Started with Initial Connectivity ...
Страница 22: ......
Страница 30: ...User s Manual 30 Document LTRT 65417 MP 11x MP 124 Reader s Notes ...
Страница 31: ...Part II Management Tools ...
Страница 32: ......
Страница 34: ...User s Manual 34 Document LTRT 65417 MP 11x MP 124 Reader s Notes ...
Страница 78: ...User s Manual 78 Document LTRT 65417 MP 11x MP 124 Reader s Notes ...
Страница 84: ...User s Manual 84 Document LTRT 65417 MP 11x MP 124 Reader s Notes ...
Страница 86: ...User s Manual 86 Document LTRT 65417 MP 11x MP 124 Reader s Notes ...
Страница 91: ...Part III General System Settings ...
Страница 92: ......
Страница 102: ...User s Manual 102 Document LTRT 65417 MP 11x MP 124 Reader s Notes ...
Страница 103: ...Part IV General VoIP Configuration ...
Страница 104: ......
Страница 162: ...User s Manual 162 Document LTRT 65417 MP 11x MP 124 Reader s Notes ...
Страница 172: ...User s Manual 172 Document LTRT 65417 MP 11x MP 124 Reader s Notes ...
Страница 199: ...Part V Gateway Application ...
Страница 200: ......
Страница 202: ...User s Manual 202 Document LTRT 65417 MP 11x MP 124 Reader s Notes ...
Страница 240: ...User s Manual 240 Document LTRT 65417 MP 11x MP 124 Reader s Notes ...
Страница 286: ...User s Manual 286 Document LTRT 65417 MP 11x MP 124 Reader s Notes ...
Страница 287: ...Part VI Stand Alone Survivability Application ...
Страница 288: ......
Страница 296: ...User s Manual 296 Document LTRT 65417 MP 11x MP 124 Reader s Notes ...
Страница 319: ...Part VII Maintenance ...
Страница 320: ......
Страница 326: ...User s Manual 326 Document LTRT 65417 MP 11x MP 124 Reader s Notes ...
Страница 347: ...Part VIII Status Performance Monitoring and Reporting ...
Страница 348: ......
Страница 377: ...Part IX Diagnostics ...
Страница 378: ......
Страница 390: ...User s Manual 390 Document LTRT 65417 MP 11x MP 124 ...
Страница 392: ...User s Manual 392 Document LTRT 65417 MP 11x MP 124 Reader s Notes ...
Страница 403: ...Part X Appendix ...
Страница 404: ......
Страница 618: ...User s Manual 618 Document LTRT 65417 MP 11x MP 124 Reader s Notes ...
Страница 622: ...User s Manual Ver 6 6 www audiocodes com ...