18
19
If the cable size is 12 AWG, you should use a 12 V power supply. And the
distance between the power supply and the device should be no more
than 40 m.
4.1. TERMINAL DESCRIPTION
The terminals contains power input, alarm input, alarm output, RS-485, Wie-
gand output, and door lock .
The terminal’s diagram is as follows:
Figure 4-1. Terminal Diagram
The descriptions of the terminals are as follows:
Table 4-1. Terminal Descriptions
Group
No.
Function
Color
Name
Description
Group A
A1
Power Input
Red
+12 V
12 VDC Power Supply
A2
Black
GND
Ground
Group B
B1
Alarm Input
Yellow/Blue
IN1
Alarm Input 1
B2
Yellow/Black
GND
Ground
B3
Yellow/Orange
IN2
Alarm Input 2
B4
Alarm Output
Yellow/Purple
NC
Alarm Output
B5
Yellow/Brown
COM
Wiring
B6
Yellow/Red
NO
Group C
C1
RS-485
Yellow
485+
RS-485 Wiring
C2
Blue
485-
C3
Black
GND
Ground
C4
Wiegand
Green
W0
Wiegand Wiring 0
C5
White
W1
Wiegand Wiring 1
C6
Brown
WG_OK
Wiegand Authenticated
C7
Orange
WG_ERR Wiegand Authentication Failed
C8
Purple
BUZZER
Buzzer Wiring
C9
Gray
TAMPER
Tampering Alarm Wiring
Group D
D1
Door Lock
White/Purple
NC
Lock Wiring (NC)
D2
White/Yellow
COM
Common
D3
White/Red
NO
Lock Wiring (NO)
D4
Yellow/Green
SENSOR
Door Contact
D5
Yellow/Gray
BTN
Exit Door Wiring
4.2. WIRE NORMAL DEVICE
You can connect the terminal with normal peripherals .
Follow the diagram below to wire the thermographic module and the device
main body:
The wiring diagram without secure door control unit is as follows .